Item |
Description |
|
Function |
Continuously lifts and removes tramp ferrous metal from a conveyor carrying hot bulk material |
|
Standard circuit limit |
NdFeB (N-grade): continuous material duty up to ~80°C |
|
Hot-duty circuit options |
Ferrite (up to 250–300°C), NdFeB H/SH/UH/EH (120–200°C), SmCo (250–350°C), Class H electromagnet (up to ~180°C coil zone, oil-cooled higher) |
|
Cleaning belt |
Standard rubber fails above ~80°C; EPDM, silicone, aramid or glass-fibre belts required for hot duty |
|
Bearings |
High-temperature grease, extended housings, optional PT100 probes |
|
Typical applications |
Clinker and cement raw mix, sinter and coke handling, calcined lime, foundry returned sand, dried biomass, hot slag and DRI lines |
|
Key benefit |
Protects crusher wear parts and liners and downstream mills from destructive steel tramp iron even when the material is too hot for a standard unit |
Direct answer: In iron removal practice, "hot material" means a conveyed burden whose surface temperature at the magnet position exceeds roughly 80°C — the continuous operating ceiling of standard neodymium circuits and of ordinary rubber cleaning belts.
A surprising number of mining and minerals flows sit above that line for at least part of the time:
· Cement clinker leaving a grate cooler commonly runs at 100–150°C at the discharge conveyor.
· Sinter, coke and pellet feed on hot-screen or hot-transfer conveyors range from 100°C to well over 200°C.
· Calcined lime and kiln feeds leave coolers between 100°C and 200°C.
· Foundry returned sand after shakeout runs at 60–150°C.
· Dried biomass, wood chips and grain from drum or belt dryers sit at 60–90°C.
· Furnace slag, sponge iron and hot DRI fines range from about 80°C to several hundred degrees.
The number that matters is not the nameplate process temperature. It is the surface temperature of the burden directly beneath the magnet face, measured across a full shift including start-up spikes, because heat reaches the separator by radiation and by conduction through the iron it captures — not just through the air. For context on how magnetic iron removal fits into the wider plant flow, see the site's overview of magnetic separation equipment and the full range of industrial magnetic separators.
Q1: Can a standard self-cleaning magnetic separator run on material at 100°C?
A: Only for short excursions. Continuous duty at 100°C exceeds the ~80°C limit of standard N-grade neodymium, so the field decays during operation and repeated exposure risks irreversible loss. Either move the magnet to a cooler point in the flowsheet or specify an H/UH-grade circuit with shielding.
Q2: What is the maximum temperature for ferrite versus neodymium circuits?
A: Ferrite tolerates roughly 250–300°C continuously — some formulations higher — but delivers only about 1,000–1,350 gauss at the face. Neodymium ranges from 80°C (N-grade) to 200°C (EH-grade) depending on grade, with much higher surface field. Match the circuit to both the temperature and the iron size you must capture.
Q3: If my magnet got too hot once, is the damage permanent?
A: Not necessarily. Cool the magnet to room temperature and re-measure with a gauss meter. If the field returns to baseline, the loss was reversible heat decay; if it stays 10% or more below baseline, the circuit has been irreversibly demagnetized and should be replaced before it protects anything critical.![]()
Direct answer: A self-cleaning magnetic separator removes iron from material above 80°C when — and only when — its magnetic circuit, belt, bearings and shielding are chosen for the actual measured temperature, not the catalogue default.
Three habits separate plants that get years of protection from plants that quietly feed steel into their crushers. First, measure the burden temperature at the magnet position and treat the peak, not the average, as the design point. Second, remember that the magnet is only one link in a thermal chain: belts, grease, chains and scrapers usually fail first and cheaply if specified correctly. Third, keep a gauss map and a temperature log so decay shows up on a dashboard before it shows up as a broken jaw plate. For a duty above 150°C, ferrite or cooled electromagnetic circuits are the proven routes; between 80°C and 200°C, high-coercivity NdFeB with a heat shield gives the best balance of capture depth and cost. If you share your belt width, tonnage and measured temperature profile, a competent supplier will size the circuit and hand you the derated performance curve — ask for it before you buy.
Contact: Annie Lu
Email: annie.lu@huataogroup.com
Phone / WhatsApp: +86 180 3242 2676
Website: http://www.tufflexscreen.com
We warmly welcome customers from around the world to contact us and establish mutually beneficial partnerships.
Osoba kontaktowa: Mr. Maple
Tel: +86 17778255675
Faks: 86--311-80690567